Loading...
menú
shop/products.hot_products
Placa base Asus GL502VS GL502VS Placa base Asus GL502VS GL502VS
Placa base Asus GL502VS GL502VS
$302.00
Mitsubishi MDS-C1-V2-4545
Mitsubishi MDS-C1-V2-4545
$1.00
MOELLER EASY 618-AC-RC
MOELLER EASY 618-AC-RC
$98.00
MOISTURE SYSTEMS CORP P21C2
MOISTURE SYSTEMS CORP P21C2
$158.00
Moto KH42JM2B063 MCNB2-28
Moto KH42JM2B063 MCNB2-28
$163.00

Phoenix PLC-RSC-24DC/21HC 2967620 Módulo de relé

{{ product.price_format }}
{{ product.origin_price_format }}
Inventario:
SKU:{{ product.sku }}
modelo: {{ product.model }}
peso: {{ product.weight }} kg

{{ variable.name }} : {{ variable.values[selectedVariantsIndex[variable_index]].name }}

{{ value.name }}

cantidad:

Fotos

Especificaciones

Maximum power dissipation for nominal condition 0.43 W
Test voltage (Winding/contact) 4 kV AC (50 Hz, 1 min., winding/contact)
Rated surge voltage 6 kV
Coil side
Nominal input voltage UN 24 V CC
Rango de tensión de entrada 20.2 V DC … 33.6 V DC (20 °C)
Nominal voltage (plugged-in electromechanical relay) 24 V CC
Drive and function monostable
Drive (polarity) polarized
Typical input current at UN 18 mA
Typical response time 8 ms
Typical release time 10 ms
Circuito de protección Reverse polarity protection; Polarity protection diode
Freewheeling diode; Freewheeling diode
Operating voltage display Yellow LED
Conmutación
Contact switching type 1 changeover contact
Type of switch contact Single contact
Contact material AgNi
Maximum switching voltage 250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC… or …FBST 500…)
Minimum switching voltage 12 V (10 mA)
Limiting continuous current 10 A
6 A (value applies to connections 12. If connections 12 are bridged, the normal value applies.)
Corriente de irrupción máxima 30 A (300 ms)
Min. switching current 10 mA (12 V)
Interrupting rating (ohmic load) max. 240 W (at 24 V DC)
58 W (at 48 V DC)
48 W (at 60 V DC)
50 W (at 110 V DC)
80 W (at 220 V DC)
2500 VA (for 250 V AC)
Interrupting rating (ohmic load) max. bridged 144 W (for 24 V DC. Value applies to connections 12. If connections 12 are bridged, the normal value applies.)
1500 VA (for 250 V AC. Value applies to connections 12. If connections 12 are bridged, the normal value applies.)
Switching capacity 2 A (at 24 V, DC13)
0.2 A (at 110 V, DC13)
0.2 A (at 250 V, DC13)
6 A (at 24 V, AC15)
6 A (at 120 V, AC15)
6 A (at 250 V, AC15)

Estado:Nuevo

solicitar_un_presupuesto

descripción_de_sus_requisitos:

shop/common.nginx_alert