Loading...
menú
shop/products.hot_products
Placa base Asus GL502VS GL502VS Placa base Asus GL502VS GL502VS
Placa base Asus GL502VS GL502VS
$302.00
Ventilador Ebmpapst 6424
Ventilador Ebmpapst 6424
$31.00
Ventilador XDR XDR4020
Ventilador XDR XDR4020
$8.00
Ventilador WYCS WYA1V15C51TBT-1
Ventilador WYCS WYA1V15C51TBT-1
$7.00
Ventilador ebm-papst W2S130-AA03-90
Ventilador ebm-papst W2S130-AA03-90
$15.00

Phoenix PSR-SCP-24UC/ESAM4/2X1/1X2 2900525 Relés de seguridad

{{ product.price_format }}
{{ product.origin_price_format }}
Inventario:
SKU:{{ product.sku }}
modelo: {{ product.model }}
peso: {{ product.weight }} kg

{{ variable.name }} : {{ variable.values[selectedVariantsIndex[variable_index]].name }}

{{ value.name }}

cantidad:

Fotos

Especificaciones

Maximum power dissipation for nominal condition 16.44 W (US = 26.4 V, IL² = 72 A², PTotal max = 2.04 W + 14.4 W)
Nominal operating mode 100% operating factor
Air clearances and creepage distances between the power circuits
Rated insulation voltage 250 V
Rated surge voltage/insulation See section “Insulation coordination”
General
Rated control circuit supply voltage US 24 V DC -15 % / +10 %
Power consumption at US typ. 1.68 W (DC)
Rated control supply current IS typ. 70 mA
Input voltage range in reference to UN 0.85 … 1.1
Typical input current at UN 70 mA DC (at Us)
Corriente de irrupción < 3.5 A (Δt = 3 ms at Us)
< 100 mA (Δt = 500 ms, with Us/Ix at S12)
> -100 mA (Δt = 300 ms, with Us/Ix at S22)
< 6 mA (with Us/Ito S34)
< 6 mA (with Us/Ito S35)
Consumo actual typ. 38 mA (S12)
typ. -38 mA (S22)
typ. 0 mA (with Us/Ito S34)
typ. 1 mA (with Us/Ito S35)
Voltage at input/start and feedback circuit approx. 24 V DC
Filter time 5 ms (at A1 in the event of voltage dips at Us)
No test pulses permitted
Typical response time 100 ms (Monitored/manual start)
150 ms (automatic start)
Typ. starting time with Us 250 ms (when controlled via A1)
Typical release time 20 ms (on demand via the sensor circuit)
45 ms (on demand via A1)
Concurrence
Recovery time 1 s (following demand of the safety function)
< 1 s (Boot time)
Circuito de protección Surge protection; Suppressor diode
Max. permissible overall conductor resistance approx. 50 Ω (Input and start circuits at US)
Operating voltage display Green LED
Status display LED (green)
Contact switching type 2 enabling current paths
1 signaling current path
Contact material AgSnO2, + 0.2 µm Au
Maximum switching voltage 250 V AC/DC
Minimum switching voltage 10 V AC/DC
Limiting continuous current 6 A (Observe derating and load limit curve)
Corriente de irrupción máxima 6 A
Inrush current, minimum 10 mA
Sq. Total current 72 A2 (Enabling current paths)
36 A2 (Signaling current path 31/32)
Interrupting rating (ohmic load) max. see load limit curve
Switching capacity min. 100 mW
Switching capacity in accordance with IEC 60947-5-1 6 A (DC13, enabling current paths)
5 A (AC15, enabling current paths)
2 A (DC13, signaling current paths)
1.5 A (AC15, signaling current paths)
Output fuse 10 A gL/gG (Enabling current paths)
4 A gL/gG (Low-demand enabling current paths)
6 A gL/gG (Signaling current path)

Estado:Nuevo

solicitar_un_presupuesto

descripción_de_sus_requisitos:

shop/common.nginx_alert